Experimental Evaluation of an Empirical Equation in a Gaseous Flow

In this paper, the estimation error of Dr. Pole's empirical equation was evaluated using copper pipes of different diameters (0.00953, 0.0127, 0.01588 m), under different flow pressure conditions (0, 300, 500, 1000, 1500, 2000, 2500, 3000 L/h). To carry out the experiments, the following instruments were used: an air compressor, 2 flow valves, a needle valve, a gas rotameter, copper piping, pressure gauges and transmitters, a Norus data logger with 4 to 20 mA output signals, thermocouples, and thermoresistors.

Investigation of Turbulence Parameters Influence on Results of CFD Modeling of Flow in Ultrasonic Flowmeter

The article investigated the influence of turbulence parameters of the SolidWorks Flow Simulations CFD package on the results of flow simulation in a two-path ultrasonic flowmeter. It has been found that the main turbulence parameters of SolidWorks Flow Simulations (turbulence intensity, turbulence length, turbulence energy and turbulence dissipation) slightly affect the result of the flow simulation in a full-filled pipeline of circular profile without additional turbulous elements (turbine, rotor, other).