Determination of electrode spacings in laboratory tanks to obtain appropriate value of electric voltage
Purpose. The aim is to study the electrical potential distribution in dimensional limited and electrically insulated volume. Мethodology. It includes numerical simulation of stationary processes in Comsol 4.3а program using DC current’s module . Results. The numerical simulation was carried out for the area of electrically insulated tank. It length was L3 = 3[m] with depth of conducting medium H = 0.4[m]. The reference areas were L10 = 10[m] and L15 = 15[m] with the same depth as the regarded tank. The reference areas represents infinite medium with conductance about 200 [S].