THE INFLUENCE OF MICROSTRUCTURE 0.45 %C STEEL ON HYDROGEN OVERVOLTAGE AT PRESENCE IRON SULFIDES
The influence of iron sulfides created on 0.45%C steel and microstructure of this steel
on hydrogen overvoltage was investigated. It was shown, that iron sulfides on the surface of
0.45%C steel, usually, decrease hydrogen overvoltage of hydrogen depolarization. The
greatest effect was created by the cansite films. Corrosion of ferrite-perlite microstructure
passes under anode control. Corrosion of troostite microstructure passes under mixed
cathode-anode control, and for sorbite and martensite microstructures it passes under cathode