Mathematical modeling of an air split-conditioner heat pump operation for investigation its exergetic efficiency
In the modern technologies related to energy transformation, namely in the field of heat pumps of air split-conditioners (“air-to-air”), an important place is occupied by apparatuses and processes, which energy perfection can be objectively evaluated only on the basis of analysis of their exergy efficiency. This allowed substantiating the actuality of the research task due to insufficient information on the exergy efficiency of the use of heat pumps of air split-conditioners and their elements.