Calculation of the underground gas store functioning parameters in the water drive mode for maintenance of gas extraction process

2016;
: pp. 208-216
https://doi.org/10.23939/mmc2016.02.208
Received: December 18, 2016

Math. Model. Comput. Vol. 3, No. 2, pp. 208-216 (2016)

1
Centre of Mathematical Modelling of Pidstryhach Institute for Applied Problems of Mechanics and Mathematics, National Academy of Sciences of Ukraine
2
Centre of Mathematical Modelling of Pidstryhach Institute for Applied Problems of Mechanics and Mathematics NAS of Ukraine

A model problem for the gas extraction process from UGS while substituting it with water is developed. The connection between the mass flowrate and pressure values in the main gas pipeline and on the outer water surface is established. A mathematic model for calculation of the UGS functioning parameters during the period of gas extraction is constructed. The results obtained are tested on the model problem.

  1. Prytula N. M., Pyanylo J. D., Prytula M. G. Undeground gas storage (mathematical models and methods). Lviv, RASTR-7 (2015), p. 266.
  2. Pyanylo J. D., Vavrychuk P. H. Calculation of the gas-water boundary speed during operation of underground gas storage. Physico-mathematical modelling and informational technologies, no. 18, 165–172 (2013).
  3. Vecherik R. L., Pyanylo J. D.,Prytula M. H., Hayetskyy J. B. Mathematical modeling of gas flow in the system reservoir of underground gas storage-main pipeline. Oil and gas, no. 6, 83–89 (2014).
  4. Carslaw H. S., Jaeger J. S. Conduction of heat in solids. Oxford University Press, Amen House, London E.C.4. (1959), p. 509.