Experimental tests of T- stubs with four bolts

Pisarek Z. Experimental tests of T-stubs with four bolts / Zdzisław Pisarek // Вісник Національного університету "Львівська політехніка". – 2013. – № 756 : Теорія і практика будівництва. – С. 215–224. – Bibliography: 5 titles.

Authors: 

Pisarek Z.

In the most common framed structures end-plate connections are utilized. In this joints are apply only two bolt rows in the tension zone with two bolts in each row. When the beam is made from H section, designers apply joints with four bolts in each row. Design rules given in Eurocode 3 relate only to bolted end-plate joints with two bolts in each bolt row. The present paper is concerned with experimental tests of welded T-stubs with four bolts. A comparison of test results with an analytical model for T-stub with four bolts is presented.

1. PN-EN 1993-1-8 Eurocode 3 (2005) Design of Steel Structures. Part 1-8 Design of Joints. CEN.
2. Kozłowski A. Pisarek Z (2008) Resistance and stiffness of T-stub with four bolts. Archives of Civil Engineering Liv. 1: 167-191.
3. Krumm R (1991) Calculation of rigid face plate connections according to the DSTV/DASt Guidelines. Stahlbau 60:
4. Ungermann D, Schmidt B (2005) Moment resistance of bolted beam to column connections with four bolts in each row. Procc. of IV European Conference on Steel and Composite Structures, Eurosteel, Maastricht:
5. Polanski Z (1984) Planowanie doświadczalne w technice. PWN, Warsaw. (in Polish).