CALCULATION OF THE AVERAGED SPECIFIC ABSORPTION RATE OF THE HUMAN ORGANISM BASED ON THE CYLINDRICAL ANTENNA MODEL

2025;
: 213-220
https://doi.org/10.23939/cds2025.01.213
Received: March 05, 2025
Revised: March 12, 2025
Accepted: March 19, 2025
Authors:
1
Lviv Polytechnic National University

International recommendations and standards for radiofrequency (RF) dosimetry of the human body use the body-averaged specific absorption coefficient (WBA-SAR) as an approximate indicator for quantifying body temperature increase. This paper proposes an analysis of the RF dosimetry of the human body during irradiation of a grounded body in the far zone of EM radiation in the frequency range of 1-200 MHz based on the cylindrical antenna model. The human body is represented by a homogeneous cylindrical monopole antenna with losses. The model makes it possible to study the influence of body mass, human height and dielectric properties of body components.

[1] IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz, IEEE Standard C95-1, 2005.

[2] ICNIRP (International Commission on Non-Ionising Radiation Protection), “Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz),” Health Phys., vol. 74, no. 4, pp. 494-522,1998.

[3] C. H. Durney, “Electromagnetic dosimetry for models of humans and animals: A review of theoretical and numerical techniques,” Proc. IEEE, vol. 68, no. 1, pp. 33-40, Jan. 1980. https://doi.org/10.1109/PROC.1980.11578

[4] O. P. Ghandi, “State of the knowledge for electromagnetic absorbed dose in man and animals,” Proc. IEEE, vol. 68, no. 1, pp. 24-32, Jan. 1980., https://doi.org/10.1109/PROC.1980.11577

[5] P. J. Dimbylow, “FDTD calculations of the whole-body average SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz,” Phys. Med. Biol., vol. 42, no. 3, pp. 479-490, 1997. https://doi.org/10.1088/0031-9155/42/3/003

[6] P. J. Dimbylow, “Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz,” Phys. Med. Biol, vol. 47, no. 16, pp. 2835-2846, 2002. https://doi.org/10.1088/0031-9155/47/16/301

[7] J. Wang, 0. Fujiwara, S. Kodera, and S. Watanabe, “FDTD calculation of whole-body average SAR in adult and child models for frequencies from 30 MHz to 3 GHz,” Phys. Med. Biol., V. 51, №17, pp. 4119-4127, 2006. https://doi.org/10.1088/0031-9155/51/17/001

[8] A.Hirata et al, "Estimation of the whole-body averaged SAR of grounded human models for plane wave exposure at respective resonance frequen­cies," Phys. Med. Biol, vol. 57, no. 24, p. 8427, 2012. https://doi.org/10.1088/0031-9155/57/24/8427

[9] A. Hirata, 0. Fujiwara, T. Nagaoka, and S. Watanabe, “Estimation of whole-body average SAR in human models due to plane-wave expo­sure at resonance frequency,” IEEE Trans. Electromagn. Compat., vol. 52, no. 1, pp. 41-48, Feb. 2010. https://doi.org/10.1109/TEMC.2009.2035613

[10] K. Yanase and A. Hirata, “Effective resistance of grounded humans for whole-body averaged SAR estimation at resonance frequencies,” Prog. Electromagn. Res. B, vol. 35, pp. 15-27, 2011. https://doi.org/10.2528/PIERB11082511

[11] R. W. P. King and S. S. Sandler, “Electric fields and currents induced in organs of the human body when exposed to ELF and VLF electromag­netic fields,” Radio Sci., vol. 31, no. 5, pp. 1153-1167, 1996. https://doi.org/10.1029/96RS01313

[12] D. Poljak and V. Roje, “Currents induced in human body exposed to the power line electromagnetic field,” Proc. 20th Annu. Conf. IEEE Eng. Med. Biol. Soc, 1998, vol. 6, pp. 3281-3284. https://doi.org/10.1109/IEMBS.1998.746198

[13] P. Ghandi and J. Chen, "Numerical dosimetry at power-line frequen­cies using anatomically based models," Bioelectromagn. Suppl, vol. 13, no. SI, pp. 43-60, 1992. https://doi.org/10.1002/bem.2250130706

[14] R. W. P. King, “Electric current and electric field induced in the human body when exposed to an incident electric field near the res­onant frequency,” IEEE Trans. Microw. Theory Techn., vol. 48, no. 9, pp. 1537-1543, Sep. 2000. https://doi.org/10.1109/22.869005

[15] B. Kibret, A. K. Teshome, and D. T. H. Lai, “Analysis of the whole-body averaged specific absorption rate (SAR) for far-field exposure of an iso­lated human body using cylindrical antenna theory,” Prog. Electromagn. Res. M, vol. 38, pp. 103-112, 2014. https://doi.org/10.2528/PIERM14072201

[16] B. Kibret, A. K. Teshome, and D. T. H. Lai, “Human body as antenna and its effect on human body communications,” Prog. Electromagn. Res., vol. 148, pp. 193-207, 2014. https://doi.org/10.2528/PIER14061207

[17] B. Kibret, A. K. Teshome, and D. T. H. Lai, “Characterizing the human body as a monopole antenna,” IEEE Trans. Antennas Propag., vol. 63, no. 10, pp. 4384-5392, 2015. https://doi.org/10.1109/TAP.2015.2456955

[18] E. Asian and O. P. Gandhi, “Human-equivalent antenna for electromagnetic fields,” U.S. Patent 5 394 164, Feb. 28,1995.

[19] T. Nozadze, V. Jeladze, R. Zaridze, “Mobile Antenna Matching Study Considering Different Holding Positions at 2100 MHz Frequency”, XXVIth International Seminar/Workshop on Direct and Inverse Problems of Electromagnetic and Acoustic Wave Theory  DIPED-2020, Tbilisi, Georgia, September 15-18, pp. 121-125, 2020. https://doi.org/10.1109/DIPED49797.2020.9273363

[20] V. Jeladze, T. Nozadze, I. Petoev-Darsavelidze, and B. Partsvania, “Mobile phone antenna-matching study with different finger positions on an inhomogeneous human model,” Electromagnetic Biology and Medicine, vol. 38, no. 4, pp.297-306, 2019. https://doi.org/10.1080/15368378.2019.1641721

[21] T. Nozadze, V. Jeladze, V. Tabatadze, I. Petoev, M. Prishvin, R. Zaridze, “Base Station Antenna's EM Exposure Study on a Homogeneous Human Model Located Inside the Car,” XXII-nd International Seminar/Workshop on Direct and Inverse Problems of Electromagnetic and Acoustic Wave Theory DIPED 2017, Dnipro, Ukraine, September 25-28,pp. 209-213, 2017 https://doi.org/10.1109/DIPED.2017.8100603

[22] R. W. P. King and T. T. Wu, “The imperfectly conducting cylindrical transmitting antenna,” IEEE Trans. Antennas Propag., vol. 14, no. 5, pp. 524-534, Sep. 1966. https://doi.org/10.1109/TAP.1966.1138733

[23] C. D. Taylor, W. H. Charles, and A. A. Eugene, “Resistive receiving and scattering antenna,” IEEE Trans. Antennas Propag., vol. 15, no. 3, pp. 371-376, May 1967. https://doi.org/10.1109/TAP.1967.1138944

[24] R. W. P. King and T. T. Wu, “The imperfectly conducting cylindrical transmitting antenna: Numerical results,” IEEE Trans. Antennas Propag., vol. AP-14, no. 5, pp. 535-542, Sep. 1966. https://doi.org/10.1109/TAP.1966.1138753

[25] S. Gabriel, R. Lau, and C. Gabriel, “The dielectric properties of biologi­cal tissues: III. Parametric models for the dielectric spectrum of tissues, “Phys. Med. Biol., vol. 41, no. 11, pp. 2271-2293, 1996. https://doi.org/10.1088/0031-9155/41/11/003

[26] H. J. Krzywicki and K. S. Chinn, “Human body density and fat of an adult male population as measured by water displacement,” Amer. J. Clin. Nutr., vol. 20, no. 4, pp. 305-310,1967. https://doi.org/10.1093/ajcn/20.4.305

[27] P. Dimbylow, “Resonance behaviour of whole-body averaged specific energy absorption rate (SAR) in the female voxel model, NAOMI,” Phys. Med. Biol., vol. 50, no. 17, p. 4053, 2005. https://doi.org/10.1088/0031-9155/50/17/009

[28] B. Kibert, A. K. Teshome, D.T. H. Lai, “Cylindrical antenna theory for the analysis of whole-body average specific absorption rate,” IEEE Trans. Antenna & Propag., vol. 63, no. 11, pp. 5224-5229, Nov. 2015. https://doi.org/10.1109/TAP.2015.2478484

[29] S. Gabriel, R. W. Lau, C. Gabriel, “The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues,” Phys. Med. Biol., vol. 41, pp. 2271. https://doi.org/10.1088/0031-9155/41/11/003