The calculation of the coefficients of linear system transfer function with the lumped constant parameters which corresponds to the preset frequency response is present.
Calculation of the transfer function on a given frequency response is the optimization problem. Direct solution has multiextremal nonlinear optimization.
Hilbert transform is applied to calculate the minimum-phase phase response. Therefore, the optimization problem of calculating the coefficients of the transfer function has complex goal function with some restrictions.