експериментальні дані

Definition of Fill Level of Ball Mill Based on Vibration Acceleration Signal

The paper is devoted to the study of the relationship between the vibration accelerometer signal and the fill level of a ball mill. It was established that there is a direct correlation between the vibration level of the front support of the mill drum and the amount of material being ground in the mill. A low vibration level corresponds to a high fill level of the mill. Two methods of processing the vibration accelerometer signal to obtain a fill level signal using a moving window are proposed.

EXPRESS ANALYSIS OF TRANSIENT ELECTROMAGNETIC DATA ACQUIRED ON THE WASTE RESERVOIR DAM IN STEBNYK

Electro­mag­ne­tic (EM) met­hods of ge­ophysics al­low to ima­ge the sub­sur­fa­ce con­duc­ti­vity distri­bu­ti­on by analyzing da­ta me­asu­red on the Earth sur­fa­ce. The tran­si­ent electro­mag­ne­tic (TEM) so­un­ding met­hod is a ti­me-do­ma­in control­led so­ur­ce one which uti­li­ze a non-sta­ti­onary tran­si­ent pro­cess of the EM fi­eld de­ca­ying in the con­duc­ti­ve me­di­um due to the step cur­rent ex­ci­ta­ti­on which is descri­bed by the He­avi­si­de functi­on.