The paper presents the analysis of scientific and technical sources on the influence of constructive features of pressure differential flowmeters on flow rate measurement error. According to the research results, the significant surface roughness of pipe sections downstream of the orifice plate does not significantly affect the flow measurement result. The influence of the pipe roughness upstream of the orifice plate depends on geometric characteristics of roughness, the pipe diameter, the relative area of the orifice plate throat, and the Reynolds number. The change in the uncertainty of the orifice discharge coefficient under conditions of inhomogeneous measuring pipe roughness in the pipe section with a length of 10D upstream of the orifice plate is analyzed. The authors have determined that even a pipe section length of 1.5D with high roughness might be enough to change the flowmeter readings by more than 1% at a large orifice diameter ratio.
- Kremlevsky, P.P., (2004) Flow meters and amount meters of substance. (in Russian)
- Pistun, E.P., Lesovoy, L.V., (2006) Regulation of variable pressure flowmeters. (in Ukrainian)
- DSTU GOST 8.586.1:2009 (ISO 5167-1:2003) Metrology. Measurement of liquid and gas flow rate by means of standard pressure differential devices. Part 1 - General principles and requirements (GOST 8.586.1-2005, IDT; ISO 5167-1:2003, MOD). – K.: Derzhspozhivstandart of Ukraine,2010. (in Ukrainian)
- DSTU GOST 8.586.2:2009 (ISO 5167-2:2003). Metrology. Measurement of flow rate and amount of liquid and gas by means of standard pressure differential devices. Part 2 - Orifice plates. Technical requirements (GOST 8.586.2-2005, IDT; ISO 5167-2:2003, MOD). – K.: Derzhspozhivstandart of Ukraine,2010. (in Ukrainian)
- DSTU GOST 8.586.3:2009 (ISO 5167-3:2003). Metrology. Measurement of flow rate and amount of liquid and gas by means of standard pressure differential devices. Part 3. Nozzles and Venturi nozzles. Technical requirements (GOST 8.586.3-2005, IDT; ISO 5167-3:2003, MOD). – K.: Derzhspozhivstandart of Ukraine,2010. (in Ukrainian)
- DSTU GOST 8.586.4:2009 (ISO 5167-4:2003). Metrology. Measurement of flow rate and amount of liquid and gas by means of standard pressure differential devices. Part 4. Venturi tubes. Technical requirements (GOST 8.586.4-2005, IDT; ISO 5167-4:2003, MOD). – K.: Derzhspozhivstandart of Ukraine,2010. (in Ukrainian)
- DSTU GOST 8.586.5:2009. Metrology. Measurement of flow rate and amount of liquid and gas by means of standard pressure differential devices. Part 5. Measurement technique (GOST 8.586.5-2005, IDT). – K.: Derzhspozhivstandart of Ukraine,2010. (in Ukrainian)
- ISO 5167-1:2003 – Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full: part 1 - General principles and requirements. ISO, 2003.
- ISO 5167-2:2003 – Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full: part 2 - Orifice plates. ISO, 2003.
- ISO 5167-3:2003 – Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full: part 3 - Nozzles and Venturi nozzles. ISO, 2003.
- ISO 5167-4:2003 – Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full: part 4 - Venturi tubes. ISO, 2003.
- ISO/TR 9464:2008 Guidelines for the use of ISO 5167:2003.
- Clark, W.J., Stephens, R.C., (1957) Flow measurement by square edged orifice plates: pipe roughness effects. Proc. Inst. Mech. Eng., 171(33), 895–904. https://doi.org/10.1243/PIME_PROC_1957_171_072_02
- ISO/TR 12767:2007 – Measurement of fluid flow by means of pressure differential devices – Guidelines on the effect of departure from the specifications and operating conditions given in ISO 5167.
- Deutsche Normen DIN 1952. Measurement of flow rate by means of standard nozzles, orifice plates and Veturi nozzles // VDI. – Durchflussmessregeln. – August 1971. (in German)
- Hobbs , J.M., Sattary, J. A. and. Maxwell, A.D, (1987) Experimental data for the determination of basic 250 mm orifice meter discharge coefficients, Commission of the European Communities, BCR Information Applied Metrology, Report EUR 10979.
- Brennan, J.A., Mcfaddin, S.E., Sindt, C.F. and Wilson, R.R., (1989) Effect of pipe roughness on orifice flow measurement. National Institute of Standards and Technology, Boulder, CO (NIST Technical Note 1329). https://doi.org/10.6028/NIST.TN.1329
- Reader-Harris, M.J., (1990) Pipe roughness and Reynolds number limits for the orifice plate discharge coefficient equation. Proceedings of the 2nd International Symposium on Fluid Flow Measurement, 6-9 June 1990, American Gas Association, Arlington, VA, 29–43.
- Studzinski, W., Berg, D., Bell, D. and Karwacki, L., (1990) Effect of meter run roughness on orifice meter accuracy. Proceedings of the 2nd International Symposium on Fluid Flow Measurement, 6-9 June 1990, American Gas Association, Arlington, VA, 1–15.
- Johansen, W.R., (1996) Effects of thin film of liquid coating orifice plate surfaces on orifice flowmeter performance. Report GRI-96/0375. Gas research institute.