New Spectrophotometric Method of Amlodipine Besylate Determination and its Validation

2018;
: pp. 429-233
1
Danylo Halytsky Lviv National Medical University
2
Zaporizhia State Medical University
3
Zaporizhia State Medical University
4
Danylo Halytsky Lviv National Medical University
5
Danylo Halytsky Lviv National Medical University
6
Danylo Halytsky Lviv National Medical University

Simple, accurate, and precise spectrophotometric method has been developed and validated for the estimation of amlodipine besylate (AML) in tablets. The method is based on the condensation of AML with sodium 1,2-naphthoquinone-4-sulphonate in an alkaline medium when the reaction mixture was heated at 363 K for 1 min to form an orange-colored product. The spectrophotometric method involved the measurement of the colored product at 459 nm. The reaction conditions were studied and optimized. Beer’s law was obeyed in the concentration range of 10–20 µg•ml-1 with RSD of 0.825 and 0.559 % and molar absorption of 2.54•104, the range of methods application is 67–133 % of the nominal content of amlodipine besylate in the dosage forms.

[1] De Portu S., Menditto E., Scalone L. et al.: Pharmacol. Res., 2006, 54, 158. https://doi.org/10.1016/j.phrs.2006.04.002
[2] Reynolds E., Martindale W.: The Extra Pharmacopoeia, 31st ed., The Royal Pharmaceutical Society, London 1996.
[3] Kavathia A., Misra M.: Arab. J. Chem., 2017, 10, 3021. https://doi.org/10.1016/j.arabjc.2013.11.043
[4] Kannappan V., Mannemala S.: J. Pharmaceut. Biomed., 2016, 120, 221. https://doi.org/10.1016/j.jpba.2015.12.048
[5] Shaalan R., Belal T., El Yazbi F., Elonsy S.: Arab. J. Chem., 2017, 10, 1381. https://doi.org/10.1016/j.arabjc.2013.04.012
[6] Vojta J., Jedlička A., Coufal P., Janečková L.: J. Pharmaceut. Biomed., 2015, 109, 36. https://doi.org/10.1016/j.jpba.2015.01.059
[7] Moon H., Yousaf A., Cho K., et al.: Asian J. Pharm. Sci., 2014, 9, 123. https://doi.org/10.1016/j.ajps.2014.04.002
[8] Moussa B., El-Zaher A., Mahrouse M., Ahmed M.: Anal. Chem. Insights, 2013, 8, 107. ttps://doi.org/10.4137/ACI.S12921
[9] Khairy M., Khorshed A., Rashwan F. et al.: Sensor. Actuator. B, 2017, 239, 768. https://doi.org/10.1016/j.snb.2016.07.165
[10] Mansano G., Eisele A., Dall’Antonia L. et al.: J. Electroanal. Chem., 2015, 738, 188. https://doi.org/10.1016/j.jelechem.2014.11.034
[11] Valezi C., Duarte E., Mansano G. et al.: Sensor. Actuator. B, 2014, 205, 234. https://doi.org/10.1016/j.snb.2014.08.078
[12] Jadon N., Jain R., Pandey A.: J. Electroanal. Chem., 2017, 788, 7. https://doi.org/10.1016/j.jelechem.2017.01.055
[13] Norouzi P., Gupta V., Larijani B.: Talanta, 2015, 131, 577. https://doi.org/10.1016/j.talanta.2014.07.033
[14] Alizadeh N., Hemati F.: B. Facult. Pharmacy, Cairo University, 2014, 52, 109. https://doi.org/10.1016/j.bfopcu.2014.01.003
[15] Shama S., Amin A., El Sayed M., Omara H.: Arab. J. Chem., 2009, 2, 59. https://doi.org/10.1016/j.arabjc.2009.07.002
[16] Basavaiah K., Chandrashekar U., Prameela H.: Il Farmaco, 2003, 58, 141. https://doi.org/10.1016/S0014-827X(02)00018-6
[17] Rahman N., Hoda M.: J. Pharmaceut. Biomed., 2003, 31, 381. https://doi.org/10.1016/S0731-7085(02)00610-6
[18] Rahman N., Azmi S.: Іl Farmaco, 2001, 56, 731. https://doi.org/10.1016/S0014-827X(01)01093-X
[19] Rahman N., Singh M., Hoda M.: Іl Farmaco, 2004, 59, 913. https://doi.org/10.1016/j.farmac.2004.07.009
[20] Iskender G., Sagirh A.: Acta Pharm. Turcica, 2000, 42, 1.
[21] Cetin G., Sungur S.: Sci. Pharm., 1995, 63, 93.
[22] Rose J.: Advanced Physico-Chemical Experiments, Pitman, London 1964.
[23] Bulatov M., Kalinin I.: Prakticheskoe Rukovodstvo po Photocolorimetricheskym Metodam Analiza, 5th edn. Khimiya, Leningrad 1986.
[24] Derzhavna Pharmacopeia Ukrainy, 1st edn. http://sphu.org/viddil-dfu/zagalnij-zmist-derzhavno%D1%97-farmakope%D1%9...