Influence of Parameters of Induction Motor-Centrifugal Pump Units with Hydropaths Connected in Series on their Modes

2015;
: pp. 85 – 90
https://doi.org/10.23939/jeecs2015.02.085
Received: November 21, 2015
Revised: December 08, 2015
Accepted: December 15, 2015

V. Lysiak. Influence of Parameters of Induction Motor-Centrifugal Pump Units with Hydropaths Connected in Series on their Modes. Energy Eng. Control Syst., 2015, Vol. 1, No. 2, pp. 85 – 90. https://doi.org/10.23939/jeecs2015.02.085

Authors:
1
Lviv Polytechnic National University

Using the mathematical model of the pump station power supply system in steady-state modes developed by the author, the influence of the parameters of induction motor-centrifugal pump units with in-series-connected hydropaths of the pumps on their steady-state modes was studied. A comparison was drawn on the operation of a number of coupled units with different pump ratings. It was revealed that the difference in rated flow of the operating fluid in centrifugal pumps results in the fact that only the unit with the lowest operating fluid rated flow works effectively. Units with larger rated flow of the operating fluid are underutilized and work with a decreased efficiency in all modes. Viability of applying centrifugal pumps with minimal difference in operating fluid rated flow for induction motor-centrifugal pump units with in-series-connected hydropaths of the pumps was substantiated.

  1. Borysenko V. P. Construction of energy saving system for electric drive in multi-pump station of DPVZ / V. P. Borysenko, S. V. Hryhoriev, V. P. Ovsiannikov, O. V. Golovin // XIII Int. Sci. and Eng. Conf. “Mechanical Engineering and Technological Area of XXI Century”: proc. in 2 vol. – Sevastopol, 2006. – Vol. 1 – P. 138–140. (in Ukrainian)
  2. Braslavskiy I. Y. Energy saving asynchronous motor / I. Y. Draslavkiy, Z. S. Shmatov, V. N. Poliakov. – Moscow : Akademia, 2004. –     256 p. (in Russian)
  3. Nikolaiev V. G. Energy-efficient ways to control the vane pump units in water supply systems in the non-stationary load [electronic resource] / V. G. Nikolaiev // Journal “Sanitary Engineering”. Heading “Water Supply”. – 2006. – No. 4. – P. 22–28. Access mode: http://www.abok.ru/for_spec/articles.php?nid=3355. – Screen name. (in Russian)
  4. Lysiak V. H. Mathematical modelling of steady-state modes of pump station power supply system // Tekhnichna Elektrodynamika Journal. – 2008. – No. 2. – P. 43–50. (in Ukrainian)
  5. Lysiak V. H. Generalized mathematical model of stationary modes of electricity supplying system of pump station / V. H. Lysiak,
    P. F. Hoholiuk // Works of Institute of Electrodynamics of National Academy of Sciences of Ukraine. – 2015. – Issue. 42. – P. 22–26.351.
    (in Ukrainian)
  6. Hoholiuk P. F., Lysiak V. H., Kostyshyn V. S. Method of calculating distribution of volume flow rate and lift for a group of induction motor-centrifugal pump units // Electric Power Engineering and Electromechanical Systems Lviv Polytechnic National University Bulletin , 2006, No.  563, pp. 27–34. (in Ukrainian)
  7. Perkhach V. S. Mathematical Problems of Electric Power Engineering / V. S. Perkhach. – Lviv : Vyshcha Shkola Publishers, 1989. – 464 p.
    (in Ukrainian)
  8. Filts R. V. Mathematical foundations of the theory of electromechanical converters / R. V. Filts. – Кyiv : Naukova Dumka Publishers, 1979. – 208 p. (in Russian)
  9. Ortega J. M. Iterative solution of nonlinear equations in several variables/ J. M. Ortega, W. C. Rheinboldt – New York and London: Academic Press, 2000. – 572 p. https://doi.org/10.1137/1.9780898719468