The arc overvoltages during the single phase to earth faults in electrical distribution grids of 6-35 kV are the object of the research in this paper. The development of 35 kV distribution electrical grids is accompanied by the construction of new overhead and cable power lines. It causes a change of the capacitive earth fault current in the grids and also affects the multiplicity of overvoltages in electrical distribution grids during the single phase to earth faults. The paper shows the research results of overvoltages during arc single phase to earth faults in 35 kV electrical grid with the different grounding modes of a grid neutral (an isolated neutral, a grounded neutral through an arc-quenching reactor, a grounded neutral through a resistor). The calculations were performed on the digital models of the investigation power grids. According to the research results, a mathematical model has been created, which allows obtaining the maximum expected multiplicity of overvoltages in 35 kV electrical grids during the single phase to earth faults. This allows making decisions about the optimal measures for the protection of an electrical equipment insulation taking into account expected values of overvoltages as early as at the stage of pre-design works for the development of such electrical grids.
- “Rules of arrangement of electrical installations. Official publication. Ministry of Energy of Ukraine”, Publishing House “Fort”, Kharkiv, 2017, 760 p. (in Ukrainian)
- N. N. Beljakov, “Investigation of overvoltages during the arc earth faults in 6 kV and 10 kV electrical grids with an isolated neutral”, Electricity, No. 5, 1957, pp. 31-36. (in Russian)
- F. A. Lihachev, “Earth faults in the electrical grids with an isolated neutral and capacitive current compensation”, Publishing House “Energy”, Moscow, 1971. (in Russian)
- F. A. Gindullin, V. G. Gol'shtejn, A. A. Dul'zon, F. H. Halilov, “Overvoltages in 6-35 kV electrical grids”, Publishing House “Jenergoatomizdat”, Moscow, 1989, 192 p. (in Russian)
- Varetsky, Y. (2019) Overvoltages in MV industrial grid under ground faults. Energy Engineering and Control Systems, 5(2), 75-80. https://doi.org/10.23939/jeecs2019.02.075
- Varetsky, Y., Bakhor, Z., Ravlyk, A. (1996) Transients in 10-35 kV electric networks with ungrounded neutrals under earth faults. Proceedings of VII International Symposium “Short Circuit Currents in Power Systems”, Warsaw, 1.20.1-1.20.4.
- Yu. O. Varetskyi, O. M. Ravlyk, Z. M. Bakhor, “Features of simulation of processes during the earth faults in the electrical grids with an isolated neutral”, Technical Electrodynamics, No. 2, 1994, pp. 61-63. (in Ukrainian)
- A. Ya. Yatseiko, K. V. Kozak, O. B. Horoshko, “Investigation of the influence of a neutral mode in the 35 kV electrical grid at the values of arc overvoltages”, Scientific papers of Donetsk National Technical University. Series: “Electrical Engineering and Power Engineering”, No. 2(15), 2013, pp. 314-318. (in Ukrainian)
- A. Ya. Yatseiko, K. V. Kozak, “Influence of a neutral mode in 6-35 kV electrical grid at the values of internal overvoltages”, Bulletin of Lviv Polytechnic National University: Electric power and electromechanical systems, No. 763, 2013, pp. 113-119. (in Ukrainian)
- V. V. Krotenok, “Calculation of overvoltages in the electrical distribution grid during the intermittent arc earth faults with the different modes of a neutral grounding”, Web Edition, URL-link: https://cyberleninka.ru/article/n/raschet-perenapryazheniy-v-raspredelit.... (in Russian)
- O. M. Ravlyk, N. O. Ravlyk, “A software complex “REC” for the analysis of processes in the electrical grids and their protection and automation systems. Certificate of registration of copyright to the work – No. 62351”, 2015. (in Ukrainian)